neiye1

O1D105 O1DLF3KG/IO-LINK

Short Description:

Reliable optical distance measurement with high ranges up to 10 m

Two switching outputs, one of them programmable as analogue output

Scalable measuring range and window function

Use in applications with background suppression

Excellent price/performance ratio



Photoelectric distance sensor

Product characteristics

Laser protection class 2

Housing rectangular

Electrical data

Operating voltage[V] 18...30 DC

Current consumption[mA] < 150

Protection class III

Reverse polarity protection yes

Typ. lifetime[h] 50000

Inputs / outputs

Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs 2

Electrical design PNP

Number of digital outputs 2

Output function normally open / normally closed; (programmable)

Max. current load per output[mA] 200

Number of analogue outputs 1

Analogue current output[mA] 4...20; (scalable IEC 61131-2)

Max. load[Ω] 250

Analogue voltage output[V] 0...10; (scalable IEC 61131-2)

Min. load resistance[Ω] 5000

Short-circuit protection yes

Type of short-circuit protection pulsed

Overload protection yes

Detection zone

Max. light spot width[mm] 15

Max. light spot height[mm] 15

Light spot dimensions refer to 10 m

Background suppression[m] 10...100

Measuring/setting range

Measuring range[m] 0.2...10; (white paper 200 x 200 mm 90% remission)

Sampling rate[Hz] 1...33

Interfaces

Communication interface IO-Link

Transmission type COM2 (38,4 kBaud)

IO-Link revision 1.1

SDCI standard IEC 61131-9

Profiles Smart Sensor: Device Identification; Device Diagnosis; Device Teach Channel; Binary Data Channel; Process Data Variable

SIO mode yes

Required master port type A

Process data analogue 2

Process data binary 2

Min. process cycle time[ms] 6

Supported DeviceIDs

Type of operation DeviceID

default 809

Operating conditions

Ambient temperature[°C] -10...60

Protection IP 67

Tests / approvals

EMC

EN 60947-5-2

Laser protection class 2

Notes on laser protection

Caution: laser light

Power: <= 4,0 mW

Wave length: 650 nm

pulse: 1,3 ns

Do not stare into beam.

Avoid exposure to the laser light.

laser class: 2

EN / IEC60825-1:2007

EN / IEC60825-1:2014

Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.

MTTF[years] 107

Mechanical data

Weight[g] 244.5

Housing rectangular

Dimensions[mm] 59 x 42 x 52

Materials housing: diecast zinc; front pane: glass; LED window: PC

Lens alignment side lens

Displays / operating elements

Display

switching status 2 x LED, yellow

operation LED, green

distance value, programming alphanumeric display, 4-digit

Accessories

Accessories (optional)

Protective cover, E21133

Remarks

Remarks

operating voltage "supply class 2" according to cULus

Pack quantity 1 pcs.

Electrical connection

Connection Connector: 1 x M12; coding: A

Other data

Parameter Setting range Factory setting

Uni mm, m, inch mm

OU1 Hno, Hnc, Fno, Fnc Hno

SP1 200...9999 1000

nSP1 200...9999 800

FSP1 200...9999 1200

OU2 Hno, Hnc, Fno, Fnc, I, U I

SP2 200...9999 2000

nSP2 200...9999 1800

FSP2 200...9999 2200

ASP 0...9999 0

AEP 0...9999 9999

rATE [Hz] 1...33 15

dS1 0...0.1...5 0

dr1 0...0.1...5 0

dS2 0...0.1...5 0

dr2 0...0.1...5 0

dFo 0...0.1...5 0

dIS d1...3; rd1...3; OFF d3

repeatability/accuracy

repeatability of the measured values accuracy

white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)

200...1000 mm ± 4.5 mm ± 6.0 mm ± 15.0 mm ± 16.0 mm

1000...2000 mm ± 5.0 mm ±8.0 mm ± 15.0 mm ± 18.0 mm

2000...4000 mm ± 16.0 mm ±19.0 mm ± 25.0 mm ± 30.0 mm

4000...6000 mm ± 24.0 mm ± 33.0 mm ± 35.0 mm ± 45.0 mm

6000...10000 mm ± 50.0 mm - ± 65.0 mm -

Sampling rate 15 Hz

Extraneous light on the object < 40 klx

repeatability/accuracy

repeatability of the measured values accuracy

white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)

200...2000 mm ± 14.0 mm ± 14.0 mm ± 24.0 mm ± 24.0 mm

2000...4000 mm ± 25.0 mm ± 30.0 mm ± 35.0 mm ± 40 mm

4000...6000 mm ± 31.0 mm ±45.0 mm ± 41.0 mm ± 55.0 mm

6000...10000 mm ± 60.0 mm - ± 70.0 mm -

Sampling rate 15 Hz

Extraneous light on the object < 40...100 klx

Range on black object (6 % remission) <= 4000 klx

The values apply at

constant ambient conditions 23 °C / 960 hPa

minimum power-on time in minutes 10