Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0...400 bar 0...5800 psi 0...40 MPa
Process connection threaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Application
Special feature Gold-plated contacts
Measuring element metallic thin film cell
Application for industrial applications
Media liquids and gases
Medium temperature[°C] -25...80
Min. bursting pressure
1700 bar 24650 psi 170 MPa
Pressure rating
800 bar 11580 psi 80 MPa
Vacuum resistance[mbar] -1000
Vacuum resistance[MPa] -0.1
Type of pressure relative pressure
Electrical data
Operating voltage[V] 18...30 DC; (to SELV/PELV)
Current consumption[mA] < 35
Min. insulation resistance[MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time[s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] 2
Permanent current rating of switching output DC[mA] 250
Switching frequency DC[Hz] < 500
Number of analogue outputs 1
Analogue current output[mA] 4...20; (scalable 1:5)
Max. load[Ω] 500
Analogue voltage output[V] 0...10; (scalable 1:5)
Min. load resistance[Ω] 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes