Measuring range
200 mm ... 30,000 mm, 90% remission factor 1) 2)
200 mm ... 17,000 mm, 18 % remission
200 mm ... 10,000 mm, 6% remission factor
Target Natural objects
Resolution 0.1 mm
Repeatability ≥ 0.5 mm 2) 3) 4)
Measurement accuracy ± 7 mm 4)
Response time 0.83 ms ... 75 ms, 0.83 ms / 3.33 ms / 8.33 ms / 25 ms / 75 ms 5) 6)
Switching frequency 1,000 Hz/250 Hz/100 Hz/33 Hz/11 Hz 5) 6)
Output time 0.33 ms/1.33 ms/3.33 ms/10 ms/30 ms 5) 7)
Light source Laser, red 8)
visible red light
Type of light Visible red light
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance) 10 mm x 10 mm (at 10 m)
Additional function
Set speed: Super Fast ... Super Slow
Teach-in, scaling and inversion of analog output
Output Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivated
Switching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB)
Teach-in, scaling and inversion of digital output
Multifunctional input: laser off / external teach / deactivated
Reset to factory default
Shape comparison: based on the distance measured over a period of time
Hold measurement value
Switch-off or lock display
Easy teach option
Average laser service life (at 25 °C) 100,000 h
Safety-related parameters
MTTFD 101 years
DCavg 0%
1) For speed setting Slow.
2) See repeatability characteristic lines.
3) Equivalent to 1 σ.
4) 6% ... 90% remission factor.
5) Depending on the set speed: Super Fast ... Super Slow.
6) Lateral entry of the object into the measuring range.
7) Continuous change of distance in measuring range.
8) Wavelength: 658 nm; max. output: 250 mW; pulse duration: 3 ns; duty cycle: 1/250.