neiye1

1047581 DT50-P1114

Short Description:

HDDM™ technology provides the best reliability, safety to ambient light and price/performance ratio

Reliable measurement and detection up to 10 m

Wide choice of models: 4 mA ... 20 mA or 0 V .. 10 V; PNP or NPN and laser class 1 or 2


1047581 DT50-P1114

Part Number 1047581

Supply voltage Vs : DC 15 V ... 30 V

Laser service life (MTTF at 25 °C): 100,000 h

Weight: 200 g

Additional function: Switch-off display

Set moving average: fast/slow

Set hysteresis

Switching mode: distance to object (DtO)

Lock user interface

Reset to factory default

Teach-in, scaling and inversion of analog output

Teach-in, scaling and inversion of switching output

Multifunctional input: laser off / external teach / deactivated

Enclosure rating: IP 65

Switching output : 1 x PNP (100 mA)

Vibration resistance: EN 60068-2-6 / EN 60068-2-64

Warm-up time: ≤ 15 min

Multifunctional input (MF) : 1 x

Typ. ambient light safety: 40 klx

Response time : 20 ms / 30 ms

Measuring range: 200 mm ... 10,000 mm, 90 % remision

200 mm ... 4,000 mm, 6 % remission

200 mm ... 6,500 mm, 18 % remission

Protection class: III

Resolution analog output: 16 bit

Analog output: 1 x 0 V ... 10 V (≥ 5 k&;937;)

Light source: Laser, red

Repeatability : 5 mm / 2.5 mm

Housing material: Die-cast zinc housing (ZNAL4CU1)

acrylic glass (PMMA)

Max. rel. humidity (not condensing): ≤ 95 %

Typ. light spot size (distance): 15 mm x 15 mm (10 m)

Power consumption : ≤ 2.1 W

Indication: 2 x LED, LC display

Resolution: 1 mm

Laser class: 2 (EN 60825-1)

Hysteresis: 10 mm ... 1,000 mm

Shock resistance: EN 60068-2-27

Ambient temperature: Operation: -30 ... +65 °C, Storage: -40 ... +75 °C

Output time : ≥ 4 ms

Connection type: Male connector, M12, 5-pin

Initialization time: ≤ 250 ms

Ripple : ≤ 5 Vpp

Accuracy : ± 10 mm


Leave Your Message


Products categories

Leave Your Message


Leave Your Message