1) This product is a standard product and does not constitute a safety component as defined
in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C,
frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information,
see document no. 8015532.
Pulses per revolution 2,000
Measuring step 90°, electric/pulses per revolution
Measuring step deviation ± 18° / pulses per revolution
Error limits ± 54° / pulses per revolution
Duty cycle ≤ 0.5 ± 5 %