General specifications
Signal type Analog input
Supply
Connection Power Rail or terminals 14+, 15-
Rated voltage Un 20 ... 35 V DC
Ripple within the supply tolerance
Power loss 1.8 W
Power consumption 2.4 W
Input
Connection terminals 1+, 2-, 3 or 5-, 6+
Input signal 0/4 ... 20 mA
Open circuit voltage/short-circuit current terminals 1+, 3-: 22.7 V / 38 mA
Voltage drop terminals 5, 6 : ≤ 2.4 V at 20 mA
Input resistance terminals 2-, 3: ≤ 76 Ω
terminals 1+, 3: ≤ 500 Ω (250 Ω load)
Available voltage terminals 1+, 3: ≥ 16 V at 20 mA
Output
Connection terminals 7-, 8+,9; 10-, 11+,12
Load 0 ... 550 Ω
Output signal 0/4 ... 20 mA (overload > 25 mA)
Ripple ≤ 50 µA rms
Transfer characteristics
Deviation at 20 °C (68 °F), 0/4 ... 20 mA
≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage
Influence of ambient temperature 0.25 µA/K
Frequency range field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 7.5 kHz (-3 dB)
control side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 7.5 kHz (-3 dB)
Settling time 200 µs
Rise time/fall time 20 µs
Electrical isolation
Output/power supply functional insulation, rated insulation voltage 50 V AC
Output/Output functional insulation, rated insulation voltage 50 V AC
Directive conformity
Electromagnetic compatibility
Directive 2004/108/EC EN 61326-1:2006
Conformity
Electromagnetic compatibility NE 21:2011
Degree of protection IEC 60529:2001
Protection against electrical shock UL 61010-1:2012
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Mass approx. 200 g
Dimensions 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 in) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection
with Ex-areas
EC-Type Examination Certificate BAS 99 ATEX 7060 , for additional certificates see www.pepperl-fuchs.com
Group, category, type of protection ¬ II (1)G [Ex ia Ga] IIC , ¬ II (1)D [Ex ia Da] IIIC
Input [Ex ia Ga] IIC, [Ex ia Da] IIIC
Supply
Maximum safe voltage Um 250 V (Attention! The rated voltage can be lower.)
Equipment terminals 1+, 3-
Voltage Uo 25.4 V
Current Io 86.8 mA
Power Po 551 mW
Permissible connection values [EEx ia]
Equipment terminals 2-, 3
Current Io/Current Ii
74 mA / 115 mA
Current Ii 115 mA
Voltage Uo 3.5 V
Current Io 74 mA
Power Po 64 mW